SCHMERSAL AES1102 (24VDC)
SCMERSAL SAFETY RELAY
- Monitoring of BNS range magnetic safety sensors
- 1 safety contact, STOP 0
GENERAL DATA | |
---|---|
Enclosure material | Glass-fibre reinforced thermoplastic, ventilated |
Material of the contacts, electrical | AgCdO |
Gross weight | 120 g |
GENERAL DATA – FEATURES | |
---|---|
Stop-Category | 0 |
Wire breakage detection | Yes |
Automatic reset function | Yes |
Reset after disconnection of supply voltage | Yes |
Integral system diagnostics, status | Yes |
Number of LEDs | 1 |
Number of normally closed (NC) | 4 |
Number of normally open (NO) | 2 |
Number of safety contacts | 1 |
Safety classification | |
Standards | EN ISO 13849-1 EN IEC 61508 |
Safety classification – Relay outputs | |
Performance Level, up to | c |
Category | 1 |
PFH value | 1.14 x 10⁻⁶ /h |
Notice | for max. 50,000 switching cycles/year and max. 80% contact load |
Safety Integrity Level (SIL), suitable for applications in | 1 |
Mission time | 20 Year(s) |
MECHANICAL DATA | |
---|---|
Mechanical life, minimum | 3,000,000 Operations |
Mounting | Snaps onto standard DIN rail to EN 60715 |
MECHANICAL DATA – CONNECTION TECHNIQUE | |
---|---|
Termination | rigid or flexibleScrew terminals M20 x 1.5 |
Terminal designations | IEC/EN 60947-1 |
Cable section, maximum | 2.5 mm² |
Tightening torque of Clips | 0.6 Nm |
MECHANICAL DATA – DIMENSIONS | |
---|---|
Width | 22.5 mm |
Height | 75 mm |
Depth | 110 mm |
ELECTRICAL DATA | |
---|---|
Frequency range | 50 Hz60 Hz |
Thermal test current | 4 A |
Rated operating voltage | 24 VDC ± 15 % |
Rated AC voltage for controls at DC minimum | 20.4 VDC |
Rated control voltage at DC, maximum | 27.6 VDC |
Electrical power consumption | 2.4 W |
Contact resistance, maximum | 0.1 Ω |
Note (Contact resistance) | in new state |
Drop-out delay in case of power failure, typically | 80 ms |
Drop-out delay in case of emergency, typically | 20 ms |
Pull-in delay at automatic start, maximum, typically | 100 ms |
Pull-in delay at RESET, typically | 20 ms |
Add comment