SCHMERSAL SRB-E-201ST

Available stocks!
GENERAL DATA
Enclosure material Glass-fibre reinforced thermoplastic, ventilated
Gross weight 130 g
GENERAL DATA – FEATURES
Stop-Category 0
Electronic Fuse Yes
Wire breakage detection Yes
Cross-circuit detection Yes
Removable Terminals Yes
Start input Yes
Feedback circuit Yes
Automatic reset function Yes
Reset edge detection Yes
Earth connection detection Yes
Integral system diagnostics, status Yes
Integral system diagnostics, error code Yes
Number of LEDs 5
Number of normally closed (NC) 2
Number of normally open (NO) 1
Number of safety digital outputs, Stop 0 2
Number of signalling outputs 1
Safety classification
EN ISO 13849-1
Standards EN IEC 62061
EN IEC 61508
Safety classification – Fail-safe digital outputs
Performance Level, up to e
Category 4
PFH value 2.66 x 10⁻⁹ /h
PFD value 2.42 x 10⁻⁵
Safety Integrity Level (SIL), suitable for applications in 3
Mission time 20 Year(s)
MECHANICAL DATA – CONNECTION TECHNIQUE
Termination rigid or flexibleScrew connection, plug-in
Terminal designations IEC/EN 60947-1
Cable section, minimum 0.25 mm²
Cable section, maximum 2.5 mm²
Tightening torque of Clips 0.5 Nm
MECHANICAL DATA – DIMENSIONS Price
Width 22.5 mm
Height 98 mm
Depth 115 mm
ELECTRICAL DATA
Rated operating voltage 24 VDC -20%/+20%, residual ripple max. 10%
Operating current 100 mA
Rated AC voltage for controls at DC minimum 19.2 VDC
Rated control voltage at DC, maximum 28.8 VDC
Electrical power consumption 2.4 W
Drop-out delay in case of power failure, typically 10 ms
Drop-out delay in case of emergency, typically 10 ms
Pull-in delay at automatic start, maximum, typically 150 ms
Pull-in delay at RESET, typically 150 ms
Switching frequency, maximum 1 Hz
ELECTRICAL DATA – SAFETY DIGITAL OUTPUTS
Voltage drop Ud, maximum 0.5 V
Leakage current Ir, maximum 1 mA
Voltage, Utilisation category DC-12 24 VDC
Current, Utilisation category DC-12 5.5 A
Voltage, Utilisation category DC-13 24 VDC
Current, Utilisation category DC-13 3.5 A
ELECTRICAL DATA – DIGITAL INPUTS
Conduction resistance, maximum 40 Ω
ELECTRICAL DATA – DIGITAL OUTPUT
Voltage, Utilisation category DC-12 24 VDC
Current, Utilisation category DC-12 0.1 A

Add comment

Comments

There are no comments yet.
Rating: 0 stars