PHOENIX CONTACT PLC-RSC-24DC-21-21 ( 2967060 )
PHOENIX CONTACT PLC-RSC-24DC-21-21 PLC-INTERFACE, consisting of basic terminal block PLC-BSC…/21 with screw connection.
PHOENIX CONTACT PLC-RSC-24DC-21-21
PLC-INTERFACE, consisting of basic terminal block PLC-BSC…/21 with screw connection and plug-in miniature relay with power contact, for assembly on DIN rail NS 35/7,5, 1 changeover contact, input voltage 24 V DC
Notes on operationSeparating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC… or FBST 500….Utilisation restriction EMC noteEMC: class A product, see manufacturer’s declaration in the download area.
Product properties | |
---|---|
Product type | Relay Module |
Application | Universal |
Operating mode | 100% operating factor |
Mechanical service life | 2x 107 cycles |
Overvoltage category | III |
Pollution degree | 3 |
Electrical properties | |
---|---|
Maximum power dissipation for nominal condition | 0.22 W |
Test voltage Winding/contact | 4 kV AC (50 Hz, 1 min., winding/contact) |
Input data | |
---|---|
Nominal input voltage UN | 24 V DC |
Input voltage range | 18.5 V DC … 33.6 V DC (20 °C) |
Typical input current at UN | 9 mA |
Typical response time | 5 ms |
Typical release time | 8 ms |
Protective circuit | Reverse polarity protection; Polarity protection diode |
Freewheeling diode; Freewheeling diode | |
Operating voltage display | Yellow LED |
Output data | |
---|---|
Contact type | 1 changeover contact |
Type of switch contact | Single contact |
Drive and function | monostable |
Drive (polarity) | bipolar |
Type of contact | Power contact |
Contact material | AgSnO |
Maximum switching voltage | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC… or …FBST 500…) |
Minimum switching voltage | 5 V (100 mA) |
Limiting continuous current | 6 A |
Maximum inrush current | 10 A (4 s) |
Min. switching current | 10 mA (12 V) |
Interrupting rating (ohmic load) max. | 140 W (at 24 V DC) 20 W (at 48 V DC) 18 W (at 60 V DC) 23 W (at 110 V DC) 40 W (at 220 V DC) 1500 VA (for 250 V AC) |
Switching capacity | 2 A (at 24 V, DC13) 0.2 A (at 110 V, DC13) 0.1 A (at 220 V, DC13) 3 A (at 24 V, AC15) 3 A (at 120 V, AC15) 3 A (at 230 V, AC15) |
Connection data | |
---|---|
Connection method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section solid | 0.14 mm² … 2.5 mm² |
Conductor cross section flexible | 0.14 mm² … 2.5 mm² |
Conductor cross section AWG | 26 … 14 |
Tightening torque | 0.6 Nm … 0.8 Nm |