SICK UE23-2MF2D3


Safety technology parameters
Integration level for security SILCL2 (EN 62061)
Category Category 3 (EN ISO 13849)
performance level PL d (EN ISO 13849)
B 10d -value 5.45 x 10 4 Wiring diagram (AC-15, 230 V, I = 3 A) 1.26 x 10 6 Wiring diagram (AC-15, 230 V, I = 1.5 A) 5.9 x 10 6 Wiring diagram (AC-15, 230 V, I = 0.75 A) 4.35 x 10 5 Wiring diagram (DC-13, 24 V, I = 2.5 A) 1 x 10 7 Wiring diagram (DC-13, 24 V, I = 0.63 A)
PFH D (average probability of dangerous outage per hour) 3.0 x 10 -6 (EN ISO 13849)
T M (lifetime) 20 years (EN ISO 13849)
Stop category 0 (EN 60204-1)
Interfaces
Connection type Fixed screw connections
Number of acknowledgment current paths (NO contact) 2, safety related
Electrical data – Operating data
Protection class II safe separation (EN 50178)
Voltage source Uv A1, A2
Signal transport (≤ 2,4 Vss) 1)
Power consumption (≤ 1 W)
Overvoltage category III
Rated insulation voltage Ui 300 V AC
Rated impulse voltage strength U imp 6 kV
Test voltage 3.5 kV (50 Hz) (EN 60439-1)
Electrical data – Control voltage: Y1-Y2-Y3
Control voltage UV – 2 V DC … UV
control current ≤ 20 mA
short circuit current ≤ 250 mA
Short circuit protection PTC-Resistance
rollback time
Manuel ≤ 70 ms
Automatic ≤ 600 ms