SICK RLY3-OSSD100
Features | |
---|---|
Applications | Output expansion module for OSSDs |
Compatible sensor types | Safety sensors with OSSDs |
Safety-related parameters | |
---|---|
Safety integrity level | SIL3 (IEC 61508)SILCL3 (IEC 62061) |
Category | Category 4 (ISO 13849-1) |
Performance level | PL e (ISO 13849-1) |
PFHD (mean probability of a dangerous failure per hour) | 1.0 x 10-9 |
TM (mission time) | 20 years (ISO 13849-1) |
Stop category | 0 (IEC 60204-1) |
Functions | |
---|---|
Path for external device monitoring (EDM) | Path for external device monitoring (EDM) |
Interfaces | |
---|---|
Connection type | Front connector with spring terminals |
Inputs | 2 safety inputs |
Outputs | 2 enabling current paths (safe)1 feedback current path (for use as external device monitoring, not safe) |
Display elements | LEDs |
Electrical data – Operating data | |
---|---|
Voltage supply | Passive (no active voltage supply) |
Power consumption (input circuits) | ≤ 1.5 W (DC) |
Electrical data – Safety inputs | |
---|---|
Number | 2 |
HIGH | 24 V DC (15 V … 30 V) |
LOW | 0 V DC (–3 V … 5 V) |
Input current | ≤ 50 mA |
Test pulse width | ≤ 1 ms |
Test pulse rate | ≤ 10 Hz |
Electrical data – Enabling current paths | |
---|---|
Response time | 12 ms |
Number | 2 |
Type of output | N/O contacts, positively guided |
Contact material | Silver alloy, gold flashed |
Switching voltage | 10 V AC … 230 V AC10 V DC … 230 V DC |
Switching current | 10 mA … 6 A |
Total current | 12 A |
Mechanical life | 1 x 107 switching cycles |
Overvoltage category | III (EN 60664-1) |
Rated impulse withstand voltage Uimp | 6 kV (EN 60664-1) |
Add comment