SCMERSAL AES1266 (24VAC/DC)
SCMERSAL SAFETY RELAY
- 2 safety contacts, STOP 0
- Monitoring of BNS range magnetic safety sensors
SPECIFICATIONS | |
---|---|
Enclosure material | Glass-fibre reinforced thermoplastic, ventilated |
Material of the contacts, electrical | Ag-Ni 10 and 0.2 µm gold-plated |
Gross weight | 174 g |
Stop-Category | 0 |
Wire breakage detection | Yes |
Cross-circuit detection | Yes |
Feedback circuit | Yes |
Automatic reset function | Yes |
Start-up test | Yes |
Reset after disconnection of supply voltage | Yes |
Earth connection detection | Yes |
Integral system diagnostics, status | Yes |
Number of LEDs | 1 |
Number of normally closed (NC) | 2 |
Number of normally open (NO) | 2 |
Number of undelayed semi-conductor outputs with signaling function | 2 |
Number of safety contacts | 2 |
Number of signalling outputs | 2 |
Termination | rigid or flexibleScrew terminals M20 x 1.5 |
Terminal designations | IEC/EN 60947-1 |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 2.5 mm² |
Tightening torque of Clips | 0.6 Nm |
Width | 22.5 mm |
Height | 100 mm |
Depth | 121 mm |
Degree of protection of the enclosure | IP40 |
Degree of protection of the mounting space | IP54 |
Degree of protection of clips or terminals | IP20 |
Ambient temperature, minimum | +0 °C |
Ambient temperature, maximum | +55 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +70 °C |
Resistance to vibrations | 10…55 Hz, Amplitude 0.35 mm, ± 15 % |
Restistance to shock | 30 g / 11 ms |
Frequency range | 50 Hz-60 Hz |
Add comment