OMRON D4N-122H
Available stocks!
Specifications | |
---|---|
Operating mechanism | Snap action |
ctuator | Adjustable roller lever 50 dia. x 8Stainless steel lever, Rubber rollerR32 to 66Form lock type |
Frequency | 50/60 Hz |
Contact form | 2NC |
Load | General load/Micro load |
Conduit | Pg13.5Number of conduit: 1 |
Ambient temperature | Operating: -30 to 70 ℃ (with no icing) |
Ambient humidity | 95% RH max. |
Permissible operating frequency | 30 operations / 1 minute max. |
Contact resistance (Initial value) | 25 mΩ max. |
Insulation resistance | 100 MΩ min. |
Impulse withstand voltage | Between each terminal of the same polarities: 2.5 kVBetween each terminal of the different polarities: 4 kVBetween each terminal and non-live-metallic part: 6 kV |
Durability | Electrical: 300,000 operations min. (10 A at 250 VAC), 500,000 operations min. (3 A at 250 VAC)Mechanical: 15,000,000 operations min. |
Vibration resistance | Malfunction: 10 to 55 Hz, 0.75 mm single amplitude |
Shock resistance | Destruction: 1000 m/s2Malfunction: 300 m/s2 |
Pollution degree | 3 (EN60947-5-1) |
Degree of protection | IP67 |
Classification of protection against electric shock | Class II (Double insulation) |
Operating Force (OF) | Standard value 4.5 N max. |
Release Force (RF) | Standard value 0.4 N min. |
Pre-Travel (PT) | Standard value 18 to 27 ° |
Movement Differential (MD) | Standard value 14 ° max. |
Over-Travel (OT) | Standard value 40 ° min. |
Total Travel (TT) | Reference value 80 ° |
Direct Opening Force | Standard value 20 N min. |
Direct Opening Travel | Standard value 50 ° min. |
Add comment